SPRUJC6A December 2024 – July 2025 AM2752-Q1 , AM2754-Q1
UHS-II Command Packet image is set to this register. The maximum length is 20 bytes. The command length varies depends on a Command Packet type. The length is specified by the UHS-II Command register.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| MMCSD0 | 0FA0 0088h |
| 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 |
| 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
| CMD_PKT_BYTE | |||||||
| R/W | |||||||
| 0h | |||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7:0 | CMD_PKT_BYTE | R/W | 0h | UHS-II Command Packet image is set to this register.The command length varies depends on a Command Packet type. Reset Source: vbus_amod_g_rst_n |