SPRUIE9D May 2017 – May 2024 DRA74P , DRA75P , DRA76P , DRA77P
| Step | Register/ Bit Field / Programming Model | Value |
|---|---|---|
| IF : Is FIFO full ? | MAILBOX_FIFOSTATUS_m[0] FIFOFULLMB | = 0x1 |
| Wait until at least one message slot is available | MAILBOX_FIFOSTATUS_m[0] FIFOFULLMB | = 0x0 |
| ELSE | ||
| Write message | MAILBOX_MESSAGE_m[31:0] MESSAGEVALUEMBM | 0x---- |
| ENDIF |