SPRUIV7C May 2022 – November 2025 AM620-Q1 , AM623 , AM625 , AM625-Q1 , AM625SIP
Stream FIFO fill level monitor. This can operate in 2 modes: 1 - Monitor peak fill level until the stream is stopped. 2 - Monitor peak fill level when the first FIFO read is made during a frame.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| CSI_RX_IF0 | 3010 1428h |
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
| RESERVED | |||||||
| NONE | |||||||
| 0h | |||||||
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| RESERVED | |||||||
| NONE | |||||||
| 0h | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | MODE | RESERVED | COUNT | ||||
| NONE | R/W | NONE | R | ||||
| 0h | 0h | 0h | 0h | ||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| COUNT | |||||||
| R | |||||||
| 0h | |||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 31:14 | RESERVED | NONE | 0h | Reserved |
| 13:12 | MODE | R/W | 0h | 00 -> Fill level detection disabled 01 -> Mode 1 10 -> Mode 2 11 -> Reserved |
| 11:10 | RESERVED | NONE | 0h | Reserved |
| 9:0 | COUNT | R | 0h | Peak fill level of FIFO. |