SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
CTRIPL Filter Control Register.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| CMPSSA0 | 5020 002Ch |
| CMPSSA1 | 5020 102Ch |
| CMPSSA2 | 5020 202Ch |
| CMPSSA3 | 5020 302Ch |
| CMPSSA4 | 5020 402Ch |
| CMPSSA5 | 5020 502Ch |
| CMPSSA6 | 5020 602Ch |
| CMPSSA7 | 5020 702Ch |
| CMPSSA8 | 5020 802Ch |
| CMPSSA9 | 5020 902Ch |
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| FILINIT | RESERVED_2 | THRESH | SAMPWIN | ||||
| R/W1TS | R | R/W | R/W | ||||
| 0h | 0h | 0h | 0h | ||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| SAMPWIN | RESERVED_1 | ||||||
| R/W | R | ||||||
| 0h | 0h | ||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | FILINIT | R/W1TS | 0h | Low filter initialization. 0 No effect 1 Initialize all samples to the filter input value |
| 14 | RESERVED_2 | R | 0h | Reserved |
| 13:9 | THRESH | R/W | 0h | Low filter majority voting threshold. At least THRESH samples of the opposite state must appear within the sample window in order for the output to change state. Threshold used is THRESH+1. |
| 8:4 | SAMPWIN | R/W | 0h | Low filter sample window size. Number of samples to monitor is SAMPWIN+1. |
| 3:0 | RESERVED_1 | R | 0h | Reserved |