SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Control registers for monitoring unit {#}
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| ECAP0 | 5024 0080h |
| ECAP1 | 5024 1080h |
| ECAP2 | 5024 2080h |
| ECAP3 | 5024 3080h |
| ECAP4 | 5024 4080h |
| ECAP5 | 5024 5080h |
| ECAP6 | 5024 6080h |
| ECAP7 | 5024 7080h |
| ECAP8 | 5024 8080h |
| ECAP9 | 5024 9080h |
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
| RESERVED_3 | |||||||
| R | |||||||
| 0h | |||||||
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| RESERVED_3 | |||||||
| R | |||||||
| 0h | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED_2 | GLDSTRBSEL | ||||||
| R | R/W | ||||||
| 0h | 0h | ||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED_1 | TRIPSEL | ||||||
| R | R/W | ||||||
| 0h | 0h | ||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 31:16 | RESERVED_3 | R | 0h | Reserved |
| 15 | RESERVED_2 | R | 0h | Reserved |
| 14:8 | GLDSTRBSEL | R/W | 0h | Global load strobe select to enable shadow to active loading 0x0 : Reserved. 0x1 to 0x7F : Global load strobe from SOC level including EPWM global load strobes. |
| 7 | RESERVED_1 | R | 0h | Reserved |
| 6:0 | TRIPSEL | R/W | 0h | Trip signal select to disable and enable signal monitoring automatically 0x0 : Disabled, Trip signals does not effect signal monitoring. 0x1 to 0x7F : Signal monioring is disabled when selected signal is high and enabled when it is low |