SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Power control for peripheral PLL.
Return to Summary Table
| Instance Name | Physical Address |
|---|---|
| MSS_TOPRCM | 5320 0800h |
| 31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
| RESERVED | |||||||
| NONE | |||||||
| 0h | |||||||
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| RESERVED | |||||||
| NONE | |||||||
| 0h | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | |||||||
| NONE | |||||||
| 0h | |||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | PLL_PER_PWRCTRL_PONIN | PLL_PER_PWRCTRL_PGOODIN | PLL_PER_PWRCTRL_RET | PLL_PER_PWRCTRL_ISORET | PLL_PER_PWRCTRL_ISOSCAN | PLL_PER_PWRCTRL_OFFMODE | |
| NONE | R/W | R/W | R/W | R/W | R/W | R/W | |
| 0h | 1h | 1h | 0h | 0h | 0h | 0h | |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 31:6 | RESERVED | NONE | 0h | Reserved |
| 5 | PLL_PER_PWRCTRL_PONIN | R/W | 1h | ON/OFF control of the weak power switch digital. For functional mode it should be 1 |
| 4 | PLL_PER_PWRCTRL_PGOODIN | R/W | 1h | ON/OFF control of the strong power switch digital. For functional mode it should be 1 |
| 3 | PLL_PER_PWRCTRL_RET | R/W | 0h | Save/Restore control for Retention mode. For functional mode it should be 0 |
| 2 | PLL_PER_PWRCTRL_ISORET | R/W | 0h | Save/Restore control for Isolation of output pins For functional mode it should be 1'b0 |
| 1 | PLL_PER_PWRCTRL_ISOSCAN | R/W | 0h | Save/Restore control for Isolation of the Scanout pins. For functional mode it should be 1'b0 |
| 0 | PLL_PER_PWRCTRL_OFFMODE | R/W | 0h | Used to switch OFF the logic on VDDA. For functional mode it should be 0 |