The time-base counter operates in one of three modes:
To illustrate the operation of the first three modes, the following timing diagrams show when events are generated and how the time-base responds to an MCPWMxSYNCI signal.
Figure 18-8 Time-Base Up-Count Mode
Waveforms
Figure 18-9 Time-Base Up-Down Count Waveforms,
TBCTL[PHSDIR = 0] Count Down On Synchronization
Event
Figure 18-10 Time-Base Up-Down Count Waveforms,
TBCTL[PHSDIR = 1] Count Up On Synchronization Event