SPRUJF2A March 2026 – March 2026 AM13E23019
It is not possible to disable SYSOSC when using a different high frequency clock to source MCLK (such as HFCLK or the PLL). This is due to SYSOSC being used by SYSCTL logic when MCLK is sourced from HFCLK or the PLL.
SYSOSC is always disabled automatically in STANDBY and SHUTDOWN modes. The DISABLE bit in the SYSOSCCFG register displays the status of SYSOSC enable/disable policy.