SPRUIM2J May 2020 – May 2026 AM2431 , AM2432 , AM2434 , AM6411 , AM6412 , AM6421 , AM6422 , AM6441 , AM6442
The Power Management Unit in AM64x consists of a Safety system.
The Safety System contains the safety comparators and temperature sensor to monitor the system supplies and temperature. The glitch filtered output of the voltage monitors is connected to the Error Signaling Module (ESM) and provide an error signal if the supply is not within the voltage thresholds set for the individual monitored supplies.