SPRUJB6B November 2024 – May 2025 AM2612
Bus Infrastructure Safety is disabled by default.
The first step is to enable Bus Safety for the MSS subsystem globally. For this, write 0x7 to MSS_CTRL.MSS_BUS_SAFETY_CTRL.MSS_BUS_SAFETY_CTRL_ENABLE.
User can enable safety on a node mentioned in above table by writing to the multibit field – MSS_CTRL.<NODE>_BUS_SAFETY_CTRL_ENABLE
Write 0x0: To disable safety for the Node