SPRUJ79A November 2024 – December 2025 F29H850TU , F29H859TU-Q1
An input capture signal (pulse train) can be prescaled by N = 2-62 (in multiples of 2) or can bypass the prescaler. This is useful when very high frequency signals are used as inputs. Figure 25-4 shows a functional diagram and Figure 25-5 shows the operation of the prescale function. The event prescaler can be reset by setting the ECCTL2.CTRFILTRESET register bit.
Figure 25-5 Prescale
Function Waveforms