SPRUJF8 May 2026 TMS320F28P551SG
Each SDFM module has four independent filter modules. These filter modules are identical and can be configured independently. Each individual filter module has the following units:
Figure 21-2 shows the SDFM module block diagram. The SDFM port operation is configured and controlled by the registers listed in SDFM Registers.
j = 11 for SDFM1 and 12 for SDFM2
y = 1 for SDFM1 and 2 for SDFM2
x = 1 to 4
Each filter module shown in Figure 21-3 has a primary (data) filter and a secondary (comparator) filter pair that receives the same bit stream. Except for the input bit stream, both the primary and secondary filter are completely independent of each other. Each of these filter modules can be independently configured. So, in a SDFM module, there is a total of four primary filters and four secondary filters.
Figure 21-3 Block Diagram of One Filter
Module