SPRUJ17I March 2022 – August 2025 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
Table 6-22 provides all the valid ADC values which correspond to the temperature measured which is read from the TOP_CTRL.TSENSE*_DATA*.DATA, TOP_CTRL.TSENSE*_RESULT.DTEMP bit fields. The table also provides the values for the temperature thresholds which are configurable through the TOP_CTRL.TSENSE*_ALERT.ALERT_THRHLD_COLD, TOP_CTRL.TSENSE*_ALERT.ALERT_THRHLD_HOT bit fields.
| ADC code | Temperature | ADC code | Temperature | ADC code | Temperature |
|---|---|---|---|---|---|
| 0-24 | 150 | 56 | 86 | 88 | 22 |
| 25 | 148 | 57 | 84 | 89 | 20 |
| 26 | 146 | 58 | 82 | 90 | 18 |
| 27 | 144 | 59 | 80 | 91 | 16 |
| 28 | 142 | 60 | 78 | 92 | 14 |
| 29 | 140 | 61 | 76 | 93 | 12 |
| 30 | 138 | 62 | 74 | 94 | 10 |
| 31 | 136 | 63 | 72 | 95 | 8 |
| 32 | 134 | 64 | 70 | 96 | 6 |
| 33 | 132 | 65 | 68 | 97 | 4 |
| 34 | 130 | 66 | 66 | 98 | 2 |
| 35 | 128 | 67 | 64 | 99 | 0 |
| 36 | 126 | 68 | 62 | 100 | -2 |
| 37 | 124 | 69 | 60 | 101 | -4 |
| 38 | 122 | 70 | 58 | 102 | -6 |
| 39 | 120 | 71 | 56 | 103 | -8 |
| 40 | 118 | 72 | 54 | 104 | -10 |
| 41 | 116 | 73 | 52 | 105 | -12 |
| 42 | 114 | 74 | 50 | 106 | -14 |
| 43 | 112 | 75 | 48 | 107 | -16 |
| 44 | 110 | 76 | 46 | 108 | -18 |
| 45 | 108 | 77 | 44 | 109 | -20 |
| 46 | 106 | 78 | 42 | 110 | -22 |
| 47 | 104 | 79 | 40 | 111 | -24 |
| 48 | 102 | 80 | 38 | 112 | -26 |
| 49 | 100 | 81 | 36 | 113 | -28 |
| 50 | 98 | 82 | 34 | 114 | -30 |
| 51 | 96 | 83 | 32 | 115 | -32 |
| 52 | 94 | 84 | 30 | 116 | -34 |
| 53 | 92 | 85 | 28 | 117 | -36 |
| 54 | 90 | 86 | 26 | 118 | -38 |
| 55 | 88 | 87 | 24 | 119-128 | -40 |