SLUUCH2 March 2021 BQ40Z50-R2
This command returns the internal temperature sensor, TS1, TS2, TS3, TS4, cell temp, FET temp, gauging temperature, user temperature, and cell voltages without IR loss compensation on ManufacturerBlockAccess() or ManufacturerData().
| Status | Condition |
|---|---|
| Activate | 0x0072 to ManufacturerBlockAccess() or ManufacturerAccess() |
Action: Output 24 bytes of temperature data values on ManufacturerBlockAccess() or ManufacturerData() in the following format: aaAAbbBBccCCddDDeeEEffFFggGGhhHHiiIIjjJJkkKKllLLmmMM where:
| Value | Description | Unit |
|---|---|---|
| AAaa | Int Temperature | 0.1 K |
| BBbb | TS1 Temperature | 0.1 K |
| CCcc | TS2 Temperature | 0.1 K |
| DDdd | TS3 Temperature | 0.1 K |
| EEee | TS4 Temperature | 0.1 K |
| FFff | Cell Temperature | 0.1 K |
| GGgg | FET Temperature | 0.1 K |
| HHhh | Gauging Temperature | 0.1 K |
| IIii | User Temperature (written by ManufacturerAccess() 0x3008 WriteTemp()) | 0.1 K |
| JJjj | Uncompensated Cell Voltage 1 | mV |
| KKkk | Uncompensated Cell Voltage 2 | mV |
| LLll | Uncompensated Cell Voltage 3 | mV |
| MMmm | Uncompensated Cell Voltage 4 | mV |