Optionally (with cycle count and SOH based degradations), by setting the configuration bit [Degrade_CC], charging current can also be degraded (in addition to charging voltage degrading). The level of degradation can be programmed using the following data flash:
- Charging current degradation on reaching CC/SOH Mode 1 (Degrade Mode 1:Current Degradation with default 10%)
- Charging Current degradation on reaching CC/SOH Mode 2 (Degrade Mode 2:Current Degradation with default 20%)
- Charging Current degradation on reaching CC/SOH Mode 3 (Degrade Mode 3:Current Degradation with default 40%)