SLUUCI8 November 2023 BQ76905
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| OTD | OTC | UTD | UTC | OTINT | HWD | VREF | VSS |
Description: Provides individual fault signals when enabled safety faults have triggered.
| Bit | Field | Description |
|---|---|---|
| 7 | OTD | Overtemperature in Discharge Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 6 | OTC | Overtemperature in Charge Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 5 | UTD | Undertemperature in Discharge Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 4 | UTC | Undertemperature in Charge Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 3 | OTINT | Internal Overtemperature Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 2 | HWD | Host Watchdog Safety Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 1 | VREF | VREF Measurement Diagnostic Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |
| 0 | VSS | VSS Measurement Diagnostic Fault 0 = Indicates protection fault has not triggered 1 = indicates protection fault has triggered |