The CC Gain and CC Delta are two calibration parameters of concern for current calibration. A known load, typically 1000 mA, is applied to the device during this process. Details on converting the CC Gain and CC Delta to floating point format are in Section 18.11, Floating Point Conversion. The host system needs to ensure the fuel gauge is UNSEALED.
The step labeled Obtain avgRawCurrent refers to Section 18.7, Obtain Raw Calibration Data.
The step labeled Convert ccGain and ccDelta to Gauge’s floating point representation and write to DF refers to Section 18.11, Floating Point Conversion.