SWRU626 December 2025 CC3501E , CC3551E
The GPTIMERs are configured in the following manner to sync to GPT0:
| GPTIMERx.CTL[2:0] MODE bit field | SYNC MODE |
|---|---|
| 0 | Disable |
| 1 | Not Synchronous |
| 2 | Not Synchronous |
| 3 | Not Synchronous |
| 4 | Not Synchronous |
| 5 | Count Up Once - Synchronous to another GPT |
| 6 | Count Up Periodically - Synchronous to another GPT |
| 7 | Count Up and Down Periodically - Synchronous to another GPT |
The event which triggers the GPTIMER should be defined in Event Manager with the GPTxEVTCTL1.SYNC register. Once the sync event arrives, the timer starts. If both timers are configured with the same sync event, both will begin counting at the same time.