AFOSC is indirectly tracked using HFOSC instead of HFXT
The Tracking loop ratio is adjusted using CKMD.HFTRACKCTL.RATIO MMR. The steps to compute the MMR values are mentioned in the AFOSC ratio section below.
The KI and KP value of the loop filter is adjusted using the MMR CKMD.LOOPCFGAF.
The filter is designed to achieve <100ppm in ~250μs and ~10ppb in a couple of seconds.