SLUUCP8A June 2024 – April 2025 BQ41Z50
The BQ41Z50 device can permanently disable the battery in the case of significant overcurrent in the DISCHARGE or RELAX state.
| Status | Condition | Action |
|---|---|---|
| Normal | Current() > SOCD:Threshold | PFAlert()[SOCD] = 0 |
| Alert | Current() ≤ SOCD:Threshold | PFAlert()[SOCD] = 1 BatteryStatus()[TDA] = 1 |
| Trip | Current() ≤ SOCD:Threshold for SOCD:Delay duration | PFAlert()[SOCD] = 1 PFStatus()[SOCD] = 1 |