SWCU191 February 2022
In this scenario the user:
Figure 20-8 shows the scenario for synchronous counter start – ignore 0 stop events.
Figure 20-8 Arbitrary Time Measurement 2
Table 20-11 lists the associated timing requirements for this scenario.
| Description | Label | Requirement |
|---|---|---|
| Minimum high time | t_minH | 42 ns |
| Minimum low time | t_minL | 126 ns |
| Minimum delay | t_d | 21 ns |