SLVUCU5 December 2025 UCD91160 , UCD91320
The block read-only command returns detailed information of the first fault.
Clearing the Log: Writing all 0's to this command clears BLACK BOX log entries (first and last). Clearing the black box log will allow to re-log the same fault in both the normal and black box logs.
| Byte Number (Write) | Byte Number (Read) | Payload Index | Description | |
|---|---|---|---|---|
| 0 | CMD = B5 | |||
| 1 | 0 | BYTE_COUNT = 16 | ||
| 2 | 1 | 0 | Bit | Description |
| 0 | paged or non-paged fault | |||
1 | Fault log valid (0)/Not valid Log(1) | |||
2 | Reserved | |||
| 7:3 | fault_page_num | |||
| 3 | 2 | 1 | Seconds & Miliseconds (Low Byte) | |
| 4 | 3 | 2 | Seconds & Miliseconds (High Byte) | |
5 | 4 | 3 | Days, Hours, & Minutes (Low Byte) | |
6 | 5 | 4 | Days, Hours, & Minutes (High Byte) | |
7 | 6 | 5 | Year & Month (Low byte) | |
8 | 7 | 6 | Year & Month (High byte) | |
9 | 8 | 7 | Fault value (low byte) see Table 26-32 | |
10 | 9 | 8 | Fault value (middle low byte) see Table 26-32 | |
11 | 10 | 9 | Fault value (middle high byte) see Table 26-32 | |
| 12 | 11 | 10 | Fault value (high byte) see Table 26-32 | |
| 13 | 12 | 11 | Bit | Description |
| 0:4 | Fault Type (see Table 26-32 | |||
5 | Fault Log Full (0) / Not Full (1) | |||
6:7 | Reserved | |||
| 14 | 13 | 12 | Rail Power Good Mask (Low Byte) | |
| 15 | 14 | 13 | Rail Power Good Mask | |
| 16 | 15 | 14 | Rail Power Good Mask | |
| 17 | 16 | 15 | Rail Power Good Mask (High Byte) | |