ZHCSR89A December   2022  – August 2023 ADS131B23

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Switching Characteristics
    8. 6.8 Timing Diagram
    9. 6.9 Typical Characteristics
  8. Parameter Measurement Information
    1. 7.1 Offset Drift Measurement
    2. 7.2 Gain Drift Measurement
    3. 7.3 Noise Performance
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Naming Conventions
      2. 8.3.2 Precision Voltage References (REFA, REFB)
      3. 8.3.3 Clocking (MCLK, OSCM, OSCD)
      4. 8.3.4 ADC1y
        1. 8.3.4.1 ADC1y Input Multiplexer
        2. 8.3.4.2 ADC1y Programmable Gain Amplifier (PGA)
        3. 8.3.4.3 ADC1y ΔΣ Modulator
        4. 8.3.4.4 ADC1y Digital Filter
        5. 8.3.4.5 ADC1y Offset and Gain Calibration
        6. 8.3.4.6 ADC1y Conversion Data
      5. 8.3.5 ADC2y
        1. 8.3.5.1 ADC2y Input Multiplexer
        2. 8.3.5.2 ADC2y Programmable Gain Amplifier (PGA)
        3. 8.3.5.3 ADC2y ΔΣ Modulator
        4. 8.3.5.4 ADC2y Digital Filter
        5. 8.3.5.5 ADC2y Offset and Gain Calibration
        6. 8.3.5.6 ADC2y Sequencer
        7. 8.3.5.7 VCMy Buffers
        8. 8.3.5.8 ADC2y Measurement Configurations
        9. 8.3.5.9 ADC2y Conversion Data
      6. 8.3.6 General-Purpose Digital Inputs and Outputs (GPIO0 to GPIO4)
        1. 8.3.6.1 GPIOx PWM Output Configuration
        2. 8.3.6.2 GPIOx PWM Input Readback
      7. 8.3.7 General-Purpose Digital Inputs and Outputs (GPIO0A, GPIO1A, GPIO0B, GPIO1B)
      8. 8.3.8 Monitors and Diagnostics
        1. 8.3.8.1  Supply Monitors
        2. 8.3.8.2  Clock Monitors
        3. 8.3.8.3  Digital Monitors
          1. 8.3.8.3.1 Register Map CRC
          2. 8.3.8.3.2 Memory Map CRC
          3. 8.3.8.3.3 GPIO Readback
        4. 8.3.8.4  Communication Monitors
        5. 8.3.8.5  Fault Flags and Fault Masking
        6. 8.3.8.6  FAULT Pin
        7. 8.3.8.7  Diagnostics and Diagnostic Procedure
        8. 8.3.8.8  Indicators
        9. 8.3.8.9  Conversion and Sequence Counters
        10. 8.3.8.10 Supply Voltage Readback
        11. 8.3.8.11 Temperature Sensor (TSA)
        12. 8.3.8.12 Test DACs (TDACA, TDACB)
        13. 8.3.8.13 Open-Wire Detection
        14. 8.3.8.14 Missing Host Detection and MHD Pin
        15. 8.3.8.15 Overcurrent Comparators (OCCA, OCCB)
          1. 8.3.8.15.1 OCCA and OCCB Pins
          2. 8.3.8.15.2 Overcurrent Indication Response Time
    4. 8.4 器件功能模式
      1. 8.4.1 Power-Up and Reset
        1. 8.4.1.1 Power-On Reset (POR)
        2. 8.4.1.2 RESETn Pin
        3. 8.4.1.3 RESET Command
      2. 8.4.2 Operating Modes
        1. 8.4.2.1 Active Mode
        2. 8.4.2.2 Standby Mode
        3. 8.4.2.3 Power-Down Mode
      3. 8.4.3 ADC Conversion Modes
        1. 8.4.3.1 ADC1y Conversion Modes
          1. 8.4.3.1.1 Continuous-Conversion Mode
          2. 8.4.3.1.2 Single-Shot Conversion Mode
          3. 8.4.3.1.3 Global-Chop Mode
            1. 8.4.3.1.3.1 Overcurrent Indication Response Time in Global-Chop Mode
        2. 8.4.3.2 ADC2y Sequencer Operation and Sequence Modes
          1. 8.4.3.2.1 Continuous Sequence Mode
          2. 8.4.3.2.2 Single-Shot Sequence Mode
          3. 8.4.3.2.3 Synchronized Single-Shot Sequence Mode Based on ADC1y Conversion Starts
    5. 8.5 Programming
      1. 8.5.1 Serial Interface
        1. 8.5.1.1 Serial Interface Signals
          1. 8.5.1.1.1 Chip Select (CSn)
          2. 8.5.1.1.2 Serial Data Clock (SCLK)
          3. 8.5.1.1.3 Serial Data Input (SDI)
          4. 8.5.1.1.4 Serial Data Output (SDO)
          5. 8.5.1.1.5 Data Ready (DRDYn)
        2. 8.5.1.2 Serial Interface Communication Structure
          1. 8.5.1.2.1 SPI Communication Frames
          2. 8.5.1.2.2 SPI Communication Words
          3. 8.5.1.2.3 STATUS Word
          4. 8.5.1.2.4 Communication Cyclic Redundancy Check (CRC)
          5. 8.5.1.2.5 Commands
            1. 8.5.1.2.5.1 NULL (0000 0000 0000 0000b)
            2. 8.5.1.2.5.2 RESET (0000 0000 0001 0001b)
            3. 8.5.1.2.5.3 LOCK (0000 0101 0101 0101b)
            4. 8.5.1.2.5.4 UNLOCK (0000 0110 0101 0101b)
            5. 8.5.1.2.5.5 WREG (011a aaaa aaa0 0nnnb)
            6. 8.5.1.2.5.6 RREG (101a aaaa aaan nnnnb)
          6. 8.5.1.2.6 SCLK Counter
          7. 8.5.1.2.7 SPI Timeout
          8. 8.5.1.2.8 Reading ADC1A, ADC1B, and ADC2A Conversion Data
          9. 8.5.1.2.9 DRDYn Pin Behavior
    6. 8.6 Register Map
      1. 8.6.1 Registers
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Unused Inputs and Outputs
      2. 9.1.2 Minimum Interface Connections
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Current-Shunt Measurement
        2. 9.2.2.2 Battery-Pack Voltage Measurement
        3. 9.2.2.3 Shunt Temperature Measurement
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Power-Supply Options
        1. 9.3.1.1 Single Unregulated External 4-V to 16-V Supply (3.3-V Digital I/O Levels)
        2. 9.3.1.2 Single Regulated External 3.3-V Supply (3.3-V Digital IO Levels)
        3. 9.3.1.3 Single Regulated External 5-V Supply (5-V Digital I/O Levels)
      2. 9.3.2 Power-Supply Sequencing
      3. 9.3.3 Power-Supply Decoupling
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10器件和文档支持
    1. 10.1 文档支持
      1. 10.1.1 相关文档
    2. 10.2 接收文档更新通知
    3. 10.3 支持资源
    4. 10.4 商标
    5. 10.5 静电放电警告
    6. 10.6 术语表
  12. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息
Continuous-Conversion Mode

In continuous-conversion mode, ADC1y converts indefinitely until stopped by the host. Set the respective STARTy bits in the CONVERSION_CTRL register to start conversions of the enabled ADC, ADC1y. Conversions on ADC1A and ADC1B can be started at different times using the respective STARTA and STARTB bits. Setting the STARTy bit while conversions are ongoing on an ADC aborts the ongoing conversion and restarts conversions. Use the STOPy bits to stop conversions of the enabled ADC, ADC1y. The currently ongoing conversion is allowed to finish after the STOPy bit is set and the digital filter is held in reset thereafter. After setting the STOPy bits, the STOPy bits read back 1b until conversions are stopped.

The STARTy bits take priority over the STOPy bits. That means if both the STARTy and STOPy bits in the CONVERSION_CTRL register are set at the same time, then conversions are started or ongoing conversions are aborted and new conversions are started.

The last conversion result of an ADC is still available for readout after conversions are stopped. The conversion results of an ADC are only cleared after a device reset, when the ADC is disabled, when the device is in standby or power-down mode, or are overwritten when a new conversion result becomes available.

The STARTy bits take effect and conversions start at the last SCLK falling edge of the register data CRC word within the SPI frame where the CONVERSION_CTRL register is written. See the Serial Interface Communication StructureSerial InterfaceSerial Interface SignalsSerial Interface Communication Structure section for details on the SPI frame of a register write command.

Setting the STARTy bit drives the DRDYn pin high if DRDYn was low, however the old conversion data can still be read until the new conversions become available.

ADC1y use a sinc3 digital filter that requires three conversion periods to settle. When conversions are started or restarted using the STARTy bits, the device hides the first two unsettled conversions and only provides a settled conversion result after the third conversion period. Use Equation 19 to calculate the time until the first conversion after a conversion start is available. All subsequent conversions have a conversion period, as shown in Figure 8-17, of tDATA = 1 / fDATA = OSR / fMOD.

Equation 19. tSETTLE = (3 × OSR + 44) × tMOD
GUID-20221007-SS0I-ZVZ4-9Q9Q-DCDM0LMSZNL0-low.svg Figure 8-17 Sinc3 Filter Settling Time and Conversion Period

The ADC does not detect when a sudden step change on the analog input occurs while the ADC is continuously converting. Therefore, the ADC continues to output conversion data at the programmed output data rate. If the step change occurs concurrently with the start of a new conversion period, then settled data are output three conversion periods after the step change. However, the sinc3 filter takes four conversion periods to provide settled data, as shown in Figure 8-18, if the step change occurs in the middle of a conversion period.

GUID-20221007-SS0I-LVQ4-7KZF-7R19N4B3HXRS-low.svg Figure 8-18 SINC3 Filter Behavior During Input Step Change