ZHCSPK7F November   2004  – January 2022 TPS2384

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagrams
    3. 8.3 Feature Description
      1. 8.3.1 PMM Faults
      2. 8.3.2 Watchdog Timer
    4. 8.4 Device Functional Modes
      1. 8.4.1  Auto Mode
      2. 8.4.2  Auto Mode Functional Description
        1. 8.4.2.1 AM Discovery
        2. 8.4.2.2 AM Classification
        3. 8.4.2.3 AM Power Delivery
      3. 8.4.3  AM Faults and INTB Output
      4. 8.4.4  Over and Undervoltage Fault
      5. 8.4.5  Over Current or Current Limit Faults
      6. 8.4.6  Undercurrent Fault (DC Modulated Disconnect)
      7. 8.4.7  Power Management Mode (PMM)
        1. 8.4.7.1 13 PMM Functions
      8. 8.4.8  PMM Discovery 1
      9. 8.4.9  PMM Discovery 2
      10. 8.4.10 PMM Classification
      11. 8.4.11 PMM Legacy
      12. 8.4.12 PMM Rup Pwr
      13. 8.4.13 PMM RDWN
    5. 8.5 Programming
      1. 8.5.1 I2C Interface Description
      2. 8.5.2 Start and Stop
      3. 8.5.3 Chip Address
      4. 8.5.4 Chip Addressing
      5. 8.5.5 Data Write Cycle
      6. 8.5.6 Port and Register Cycle
      7. 8.5.7 Data Read Cycle
    6. 8.6 Register Maps
      1. 8.6.1 Register/Port Addressing Map
      2. 8.6.2 Common Read, Register Select
      3. 8.6.3 Common Write, Register Select = 1111 (Test Register)
      4. 8.6.4 Common Control Write, Register Select = 0001
      5. 8.6.5 Port Control Write 1, Register Select = 0010 (One Per Port)
      6. 8.6.6 Port Control Write 2, Register Select = 0011 (One Per Port)
      7. 8.6.7 Port Status Read 1, Register Select = 0100 (One Per Port)
      8. 8.6.8 Port Status Read 2, Register Select = 0101 (One Per Port)
      9. 8.6.9 A/D Results Registers (Discovery Current, Voltage, Current and Temperature)
        1. 8.6.9.1 Discovery Current — Lower Bits, Register Select = 0110 (One Per Port)
        2. 8.6.9.2 Discovery Current — Upper Bits, Register Select = 0111 (One Per Port)
        3. 8.6.9.3 Voltage — Lower Bits, Register Select = 1000 (One Per Port)
        4. 8.6.9.4 Voltage — Upper Bits, Register Select = 1001 (One Per Port)
        5. 8.6.9.5 Current — Lower Bits, Register Select = 1010 (One Per Port)
        6. 8.6.9.6 Current — Upper Bits, Register Select = 1011 (One Per Port)
        7. 8.6.9.7 Temperature — Lower Bits, Register Select = 1100 (One Per Port)
        8. 8.6.9.8 Temperature — Upper Bits, Register Select = 1101 (One Per Port)
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 AC Disconnect Drive Circuit Detail
      2. 9.1.2 Connection of Unused Ports and Pins
      3. 9.1.3 Opto-isolator Interface
      4. 9.1.4 Port Protection from Electrical Transients
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Power Pin Bypass Capacitors
        2. 9.2.2.2 Per Port Components
        3. 9.2.2.3 Bias and Timing
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 Local Circuits
      2. 11.1.2 System Protection Circuits
    2. 11.2 Layout Example
    3. 11.3 Thermal Consideration
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 接收文档更新通知
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 术语表
  13. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Port Control Write 1, Register Select = 0010 (One Per Port)

Figure 8-23 Port Control Write 1, Register Select = 0010 (One Per Port)
76543210
UnusedUnusedDiscovery fault disableDC Disconnect disableFunction Bit 3Function Bit 2Function Bit 1Function Bit 0
R/WR/WR/WR/WR/WR/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 8-6 Port Control Write 1, Register Select = 0010 (One Per Port)
BitFieldTypeResetDescription
D7Unused00
D6Unused00
D5Discovery fault disableR/W00 = normal operation
1 = disable internal discovery fault limits (19 kΩ to 29.5 kΩ)
D4DC Disconnect disableR/W00 = DC Disconnect active
1 = DC Disconnect disable (for AC Disconnect)
D3Function Bit 3R/W00000000 = Disable function (power down and reset all functions)
0001 = Discovery 1 function
0010 = Discovery 2 function
0011 = port voltage sample function (V sample)
0100 = legacy detection function
0101 = classification function
0110 = ramp up/power function (rup pwr)
0111 = continuous sample function (C sample)
1000 = ramp power down function (Rdwn)
1001 = ac low
1010 = ac high
1011 = port current sample function (I sample)
1100 = die temperature sample function (T sample)
1101 = spare
1110 = spare
1111 = spare
D2Function Bit 2R/W
D1Function Bit 1R/W
D0Function Bit 0R/W