ZHCSZ22A October 2025 – December 2025 LM5066H
PRODUCTION DATA
OC_BLANKING_TIMERS 寄存器是特定于制造商的命令,用于配置或读取 LM5066Hx 器件中过流消隐计时器的设置信息。
此命令使用 PMBus 读取或写入字节协议。
| 位 | 名称 | 值 | 过流消隐计时器持续时间 (ms) | 默认值 |
|---|---|---|---|---|
| 7:4 | 过流 Blanking2 计时器 | 0xFh | 95 | 0x7h |
| 0xEh | 9.5 | |||
| 0xDh | 4.75 | |||
| 0xCh | 3.8 | |||
| 0xBh | 2.85 | |||
| 0xAh | 1.9 | |||
| 0x9h | 0.95 | |||
| 0x8h | 0.76 | |||
| 0x7h | 0.57 | |||
| 0x6h | 0.38 | |||
| 0x5h | 0.285 | |||
| 0x4h | 0.19 | |||
| 0x3h | 0.095 | |||
| 0x2h | 0.057 | |||
| 0x1h | 0.038 | |||
| 0x0h | 0 | |||
| 3:0 | 过流 Blanking1 计时器 | 0xFh | 95 | 0x5h |
| 0xEh | 76 | |||
| 0xDh | 57 | |||
| 0xCh | 38 | |||
| 0xBh | 19 | |||
| 0xAh | 14.25 | |||
| 0x9h | 9.5 | |||
| 0x8h | 7.6 | |||
| 0x7h | 3.8 | |||
| 0x6h | 1.9 | |||
| 0x5h | 0.95 | |||
| 0x4h | 0.7125 | |||
| 0x3h | 0.475 | |||
| 0x2h | 0.095 | |||
| 0x1h | 0.019 | |||
| 0x0h | 0 |