SLLSFZ8 November   2025 MCF8329HS-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings Auto
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Characteristics of the SDA and SCL bus for Standard and Fast mode
    7. 6.7 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Three Phase BLDC Gate Drivers
      2. 7.3.2  Gate Drive Architecture
        1. 7.3.2.1 Dead time and Cross Conduction Prevention
      3. 7.3.3  AVDD Linear Voltage Regulator
      4. 7.3.4  Low-Side Current Sense Amplifier
      5. 7.3.5  Device Interface Modes
        1. 7.3.5.1 Interface - Control and Monitoring
        2. 7.3.5.2 I2C Interface
      6. 7.3.6  Motor Control Input Options
        1. 7.3.6.1 Analog-Mode Motor Control
        2. 7.3.6.2 PWM-Mode Motor Control
        3. 7.3.6.3 Frequency-Mode Motor Control
        4. 7.3.6.4 I2C based Motor Control
        5. 7.3.6.5 Input Control Signal Profiles
          1. 7.3.6.5.1 Linear Control Profiles
          2. 7.3.6.5.2 Staircase Control Profiles
          3. 7.3.6.5.3 Forward-Reverse Profiles
          4. 7.3.6.5.4 Multi-Reference Mode Operation
          5. 7.3.6.5.5 Input Reference Transfer Function without Profiler
      7. 7.3.7  Bootstrap Capacitor Initial Charging
      8. 7.3.8  Starting the Motor Under Different Initial Conditions
        1. 7.3.8.1 Case 1 – Motor is Stationary
        2. 7.3.8.2 Case 2 – Motor is Spinning in the Forward Direction
        3. 7.3.8.3 Case 3 – Motor is Spinning in the Reverse Direction
      9. 7.3.9  Motor Start Sequence (MSS)
        1. 7.3.9.1 Initial Speed Detect (ISD)
        2. 7.3.9.2 Motor Resynchronization
        3. 7.3.9.3 Reverse Drive
          1. 7.3.9.3.1 Reverse Drive Tuning
        4. 7.3.9.4 Motor Start-up
          1. 7.3.9.4.1 Align
          2. 7.3.9.4.2 Double Align
          3. 7.3.9.4.3 Initial Position Detection (IPD)
            1. 7.3.9.4.3.1 IPD Operation
            2. 7.3.9.4.3.2 IPD Release
            3. 7.3.9.4.3.3 IPD Advance Angle
          4. 7.3.9.4.4 Slow First Cycle Startup
          5. 7.3.9.4.5 Open Loop
          6. 7.3.9.4.6 Transition from Open to Closed Loop
      10. 7.3.10 Closed Loop Operation
        1. 7.3.10.1 Closed loop accelerate
        2. 7.3.10.2 Speed PI Control
        3. 7.3.10.3 Current PI Control
        4. 7.3.10.4 Overmodulation
        5. 7.3.10.5 Power Loop
        6. 7.3.10.6 Modulation Index Control
        7. 7.3.10.7 Motor Speed Limit
        8. 7.3.10.8 Input DC Power Limit
      11. 7.3.11 Maximum Torque Per Ampere (MTPA) Control
      12. 7.3.12 Flux Weakening Control
      13. 7.3.13 Motor Parameters
        1. 7.3.13.1 Motor Resistance
        2. 7.3.13.2 Motor Inductance
        3. 7.3.13.3 Motor Back-EMF constant
      14. 7.3.14 Motor Parameter Extraction Tool (MPET)
      15. 7.3.15 Single Hall Sensor Operation
      16. 7.3.16 Anti-Voltage Surge (AVS)
      17. 7.3.17 Active Braking
      18. 7.3.18 Output PWM Switching Frequency
      19. 7.3.19 Dead Time Compensation
      20. 7.3.20 Voltage Sense Scaling
      21. 7.3.21 Motor Stop Options
        1. 7.3.21.1 Coast (Hi-Z) Mode
        2. 7.3.21.2 Recirculation Mode
        3. 7.3.21.3 Low-Side Braking
        4. 7.3.21.4 Active Spin-Down
      22. 7.3.22 FG Configuration
        1. 7.3.22.1 FG Output Frequency
        2. 7.3.22.2 FG in Open-Loop
        3. 7.3.22.3 FG During Motor Stop
        4. 7.3.22.4 FG Behavior During Fault
      23. 7.3.23 Protections
        1. 7.3.23.1  PVDD Supply Undervoltage Lockout (PVDD_UV)
        2. 7.3.23.2  AVDD Power on Reset (AVDD_POR)
        3. 7.3.23.3  GVDD Undervoltage Lockout (GVDD_UV)
        4. 7.3.23.4  BST Undervoltage Lockout (BST_UV)
        5. 7.3.23.5  MOSFET VDS Overcurrent Protection (VDS_OCP)
        6. 7.3.23.6  VSENSE Overcurrent Protection (SEN_OCP)
        7. 7.3.23.7  Thermal Shutdown (OTSD)
        8. 7.3.23.8  Hardware Lock Detection Current Limit (HW_LOCK_ILIMIT)
          1. 7.3.23.8.1 HW_LOCK_ILIMIT Latched Shutdown (HW_LOCK_ILIMIT_MODE = 00xb or 010b)
          2. 7.3.23.8.2 HW_LOCK_ILIMIT Automatic recovery (HW_LOCK_ILIMIT_MODE = 011b or 10xb)
          3. 7.3.23.8.3 HW_LOCK_ILIMIT Report Only (HW_LOCK_ILIMIT_MODE = 110b)
          4. 7.3.23.8.4 HW_LOCK_ILIMIT Disabled (HW_LOCK_ILIMIT_MODE = 111b)
        9. 7.3.23.9  Lock Detection Current Limit (LOCK_ILIMIT)
          1. 7.3.23.9.1 LOCK_ILIMIT Latched Shutdown (LOCK_ILIMIT_MODE = 00xb or 010b)
          2. 7.3.23.9.2 LOCK_ILIMIT Automatic Recovery (LOCK_ILIMIT_MODE = 011b or 10xb)
          3. 7.3.23.9.3 LOCK_ILIMIT Report Only (LOCK_ILIMIT_MODE = 110b)
          4. 7.3.23.9.4 LOCK_ILIMIT Disabled (LOCK_ILIMIT_MODE = 111b)
        10. 7.3.23.10 Motor Lock (MTR_LCK)
          1. 7.3.23.10.1 MTR_LCK Latched Shutdown (MTR_LCK_MODE = 00xb or 010b)
          2. 7.3.23.10.2 MTR_LCK Automatic Recovery (MTR_LCK_MODE = 011b or 10xb)
          3. 7.3.23.10.3 MTR_LCK Report Only (MTR_LCK_MODE = 110b)
          4. 7.3.23.10.4 MTR_LCK Disabled (MTR_LCK_MODE = 111b)
        11. 7.3.23.11 Motor Lock Detection
          1. 7.3.23.11.1 Lock 1: Abnormal Speed (ABN_SPEED)
          2. 7.3.23.11.2 Lock 2: Abnormal BEMF (ABN_BEMF)
          3. 7.3.23.11.3 Lock3: No-Motor Fault (NO_MTR)
        12. 7.3.23.12 MPET Faults
        13. 7.3.23.13 IPD Faults
        14. 7.3.23.14 Dry Run Detection
    4. 7.4 Device Functional Modes
      1. 7.4.1 Functional Modes
        1. 7.4.1.1 Sleep Mode
        2. 7.4.1.2 Standby Mode
        3. 7.4.1.3 Fault Reset (CLR_FLT)
    5. 7.5 External Interface
      1. 7.5.1 DRVOFF - Gate Driver Shutdown Functionality
      2. 7.5.2 Oscillator Source
      3. 7.5.3 External Watchdog with MCU Reset
    6. 7.6 EEPROM access and I2C interface
      1. 7.6.1 EEPROM Access
        1. 7.6.1.1 EEPROM Write
        2. 7.6.1.2 EEPROM Read
        3. 7.6.1.3 EEPROM Security
      2. 7.6.2 I2C Serial Interface
        1. 7.6.2.1 I2C Data Word
        2. 7.6.2.2 I2C Write Operation
        3. 7.6.2.3 I2C Read Operation
        4. 7.6.2.4 Examples of I2C Communication Protocol Packets
        5. 7.6.2.5 Internal Buffers
        6. 7.6.2.6 CRC Byte Calculation
  9. EEPROM (Non-Volatile) Register Map
    1. 8.1 Algorithm_Configuration Registers
    2. 8.2 Fault_Configuration Registers
    3. 8.3 Hardware_Configuration Registers
    4. 8.4 Internal_Algorithm_Configuration Registers
  10. RAM (Volatile) Register Map
    1. 9.1 Fault_Status Registers
    2. 9.2 System_Status Registers
    3. 9.3 Algorithm_Control Registers
    4. 9.4 Device_Control Registers
    5. 9.5 Algorithm_Variables Registers
  11. 10Typical Applications
    1. 10.1 Application Information
    2. 10.2 Typical Applications
      1.      Detailed Design Procedure
      2.      Bootstrap Capacitor and GVDD Capacitor Selection
      3.      Gate Drive Current
      4.      Gate Resistor Selection
      5.      System Considerations in High Power Designs
      6.      Capacitor Voltage Ratings
      7.      External Power Stage Components
    3. 10.3 Power Supply Recommendations
      1. 10.3.1 Bulk Capacitance
    4. 10.4 Layout
      1. 10.4.1 Layout Guidelines
      2. 10.4.2 Layout Example
      3. 10.4.3 Thermal Considerations
        1. 10.4.3.1 Power Dissipation
  12. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Support Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  13. 12Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

PWM-Mode Motor Control

PWM-based motor control can be configured by setting SPEED_MODE to 01b. In this mode, the PWM duty cycle applied to the SPEED/WAKE pin can be varied from 0 to 100%, and duty command (DUTY_CMD) varies linearly with the applied PWM duty cycle. When 0 ≤ DutySPEED ≤ DutyEN_SB, DUTY_CMD is set to zero. When DutyEX_SB ≤ DutySPEED ≤ 100%, DUTY_CMD varies linearly with DutySPEED as shown in Figure 7-6. DutyEX_SB and DutyEN_SB are the standby entry and exit thresholds - refer Section 7.4.1.2 for more information on DutyEX_SB and DutyEN_SB. The frequency of the PWM input signal applied to the SPEED/WAKE pin is defined as fPWM and the range for this frequency can be configured through SPEED_RANGE_SEL.

Note:
  1. fPWM is the frequency of the PWM signal the device can accept at the SPEED/WAKE pin to control motor speed. It does not correspond to the PWM output frequency that is applied to the motor phases. The PWM output frequency can be configured through PWM_FREQ_OUT (see Section 7.3.18).
  2. SLEEP_ENTRY_TIME should be set longer than the off time in the PWM signal (VSPEED < VIL) at the lowest duty input. For example, if fPWM is 10 kHz and the lowest duty input is 2%, SLEEP_ENTRY_TIME should be more than 98 µs to ensure there is no unintended sleep/standby entry.
MCF8329HS-Q1 PWM-Mode Motor
                                        Control Figure 7-6 PWM-Mode Motor Control