SBASB61 August 2026 ADS124S18
PRODUCTION DATA
The device is also reset through SPI operation by inputting a special bit pattern on SDI. The input pattern does not follow the regular SPI command format. Two input patterns are available to reset the ADC.
Pattern 1 consists of a minimum 1023 consecutive ones followed by one zero. The device resets on the falling edge of SCLK when the final zero is shifted in. This pattern can be used in either 3- or 4-wire SPI mode. Figure 7-17 shows a pattern 1 reset example.
Reset pattern 2 is only for use with 4-wire SPI mode. To reset, input a minimum of 1024 consecutive ones (no ending zero value), followed by taking CS high at which time the reset occurs. Use pattern 2 when multiple devices are connected in a daisy-chain. Figure 7-18 shows a pattern 2 reset example.
Figure 7-17 Reset Pattern 1
Figure 7-18 Reset Pattern 2