SBASB61 August   2026 ADS124S18

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Switching Characteristics
    8. 5.8 Timing Diagrams
    9. 5.9 Typical Characteristics
  7. Parameter Measurement Information
    1. 6.1 Noise Performance
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Analog Inputs and Multiplexer
      2. 7.3.2  Programmable Gain Amplifier (PGA)
      3. 7.3.3  Voltage Reference
        1. 7.3.3.1 Internal Reference
        2. 7.3.3.2 External Reference
        3. 7.3.3.3 Reference Buffers
      4. 7.3.4  Power-Scalable Speed Modes
      5. 7.3.5  Clock Source
      6. 7.3.6  Delta-Sigma Modulator
      7. 7.3.7  Digital Filter
        1. 7.3.7.1 Sinc3 and Sinc4 Filters
        2. 7.3.7.2 Sinc4 + Sinc1 Filter
        3. 7.3.7.3 FIR Filter
        4. 7.3.7.4 50Hz and 60Hz Line Cycle Rejection
        5. 7.3.7.5 Digital Filter Latency
        6. 7.3.7.6 Global-Chop Mode
      8. 7.3.8  Excitation Current Sources (IDACs)
      9. 7.3.9  Burn-Out Current Sources (BOCS)
      10. 7.3.10 Bias Voltage Generator (VBIAS)
      11. 7.3.11 General Purpose IOs (GPIOs)
        1. 7.3.11.1 ALERT Output
        2. 7.3.11.2 FAULT Output
      12. 7.3.12 Offset and Gain Calibration Coefficients
      13. 7.3.13 Digital Comparator
      14. 7.3.14 System Monitors
        1. 7.3.14.1 Internal Short (Offset Calibration)
        2. 7.3.14.2 Internal Temperature Sensor
        3. 7.3.14.3 External Reference Voltage Readback
        4. 7.3.14.4 Power-Supply Readback
      15. 7.3.15 Monitors and Status Flags
        1. 7.3.15.1 Reset (RESETn flag)
        2. 7.3.15.2 AVDD Undervoltage Monitor (AVDD_UVn flag)
        3. 7.3.15.3 Reference Undervoltage Monitor (REF_UVn flag)
        4. 7.3.15.4 SPI CRC Fault (SPI_CRC_FAULTn flag)
        5. 7.3.15.5 Register Map CRC Fault (REG_MAP_CRC_FAULTn flag)
        6. 7.3.15.6 Internal Memory Fault (MEM_FAULTn flag)
        7. 7.3.15.7 Register Write Fault (REG_WRITE_FAULTn flag)
        8. 7.3.15.8 Digital Comparator Alert (COMP_ALERTn flag)
    4. 7.4 Device Functional Modes
      1. 7.4.1 Power-up and Reset
        1. 7.4.1.1 Power-On Reset (POR)
        2. 7.4.1.2 RESET Pin
        3. 7.4.1.3 Reset by Register Write
        4. 7.4.1.4 Reset by SPI Input Pattern
      2. 7.4.2 Operating Modes
        1. 7.4.2.1 Idle and Standby Mode
        2. 7.4.2.2 Power-Down Mode
        3. 7.4.2.3 Sequencer Mode
          1. 7.4.2.3.1 Configuring the Sequencer
          2. 7.4.2.3.2 Starting and Stopping the Sequencer (START/STOP bits and START pin)
          3. 7.4.2.3.3 Sequencer Status Bits
    5. 7.5 Programming
      1. 7.5.1  Serial Interface (SPI)
      2. 7.5.2  Serial Interface Signals
        1. 7.5.2.1 Chip Select (CS)
        2. 7.5.2.2 Serial Clock (SCLK)
        3. 7.5.2.3 Serial Data Input (SDI)
        4. 7.5.2.4 Serial Data Output/Data Ready (SDO/DRDY)
        5. 7.5.2.5 Data Ready (DRDY) Pin
      3. 7.5.3  Serial Interface Communication Structure
        1. 7.5.3.1 SPI Frame
        2. 7.5.3.2 STATUS Header
        3. 7.5.3.3 SPI CRC
      4. 7.5.4  Device Commands
        1. 7.5.4.1 No Operation (Read Conversion Data)
        2. 7.5.4.2 Read Register Command
        3. 7.5.4.3 Write Register Command
      5. 7.5.5  Continuous-Read Mode
        1. 7.5.5.1 Read Registers in Continuous-Read Mode
      6. 7.5.6  Daisy-Chain Operation
      7. 7.5.7  3-Wire SPI Mode
        1. 7.5.7.1 3-Wire SPI Mode Frame Re-Alignment
      8. 7.5.8  Monitoring for New Conversion Data
        1. 7.5.8.1 DRDY Pin or SDO/DRDY Pin Monitoring
        2. 7.5.8.2 Reading DRDY Bit and Conversion Counter
        3. 7.5.8.3 Clock Counting
      9. 7.5.9  DRDY Pin Behavior
      10. 7.5.10 Register Map CRC
      11. 7.5.11 Conversion Data Format
  9. Register Map
    1. 8.1 Status and General Configuration Page Registers
    2. 8.2 Step Configuration Page Registers
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Serial Interface Connections
      2. 9.1.2 Unused Inputs and Outputs
      3. 9.1.3 Interfacing With Multiple Devices
      4. 9.1.4 Device Initialization and Starting the Sequencer
      5. 9.1.5 Sequencer Configuration Strategy Example
    2. 9.2 Typical Applications
      1. 9.2.1 Software-Configurable RTD Measurement Input
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Performance Plots
        4. 9.2.1.4 Design Variant – 3-Wire RTD Measurement With Automatic Lead-Wire Compensation Using Two IDACs
      2. 9.2.2 Thermocouple Measurement With Cold-Junction Compensation Using a 2-wire RTD
      3. 9.2.3 Resistive Bridge Sensor Measurement With Temperature Compensation
      4. 9.2.4 Autonomous Power Supply Monitoring
        1. 9.2.4.1 Design Requirements
        2. 9.2.4.2 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Power Supplies
      2. 9.3.2 Power-Supply Sequencing
      3. 9.3.3 Power-Supply Decoupling
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Read Register Command

Use the read register command to read register data. The command follows a two-frame protocol in which the read command is sent in one frame and the ADC responds with register data in the next frame. The first byte of the command is the base command value (40h) added to the 6-bit register address. The value of the second command byte is arbitrary, but is used together with the first byte for the CRC calculation.

Figure 7-29 shows an example of reading register data for the 24-bit device with the STATUS header and CRC disabled. Frame 1 is the command frame and frame 2 is the data response frame. The frames are delimited by taking CS high. The data response frame returns the requested register data byte, followed by the register address indication byte, and a 00h padded byte to complete the 24-bit frame. The register data is most-significant-bit first aligned. The 6-bit register address is right-aligned within the register address indication byte (padded with 00b at the MSB position). If desired, the data response frame can be shortened after the register data byte by taking CS high.

Reading from a register address outside the valid address range returns 00h as the register data and FFh in the register address indication byte to indicate an error.

When reading multiple registers, full-duplex operation can be used to double the throughput of the read register operations by inputting the next read register command during the data response frame of the previous register.

ADS114S14 ADS114S18 ADS124S14 ADS124S18 Read Register Data (24-Bit
                    Device, STATUS Header and CRC Disabled)
Previous state of SDO/DRDY before first SCLK.
Data are either 24 bits of conversion data, or if the read register command is sent in the prior frame, the data field is the register data byte + address indication byte + 00h padding.
Figure 7-29 Read Register Data (24-Bit Device, STATUS Header and CRC Disabled)

Figure 7-30 shows an example of a register read operation for the 24-bit device with the STATUS header and CRC enabled. In frame 1, conversion data are output at the same time as the read register command is input (when the previous frame is not a read register command). The input command is padded with three don't care bytes to match the length of the output data frame. The padded input bytes are excluded from the CRC-IN code calculation. Frame 2 shows the input of the next command concurrent with the output of the requested register data. The CRC-OUT code includes all preceding bytes within the data output frame.

ADS114S14 ADS114S18 ADS124S14 ADS124S18 Read Register Data (24-Bit
                    Device, STATUS Header and CRC Enabled)
Optional CRC byte. If CRC is disabled, the frame shortens by one byte.
Optional STATUS header. If STATUS is disabled, the frame shortens by two bytes.
Depending on the previous operation, the data field is either conversion data or the register data byte + address indication byte + 00h padding.
Previous state of SDO/DRDY before the first SCLK.
Figure 7-30 Read Register Data (24-Bit Device, STATUS Header and CRC Enabled)