ZHCSB89H May 2013 – December 2021 TPS65310A-Q1
PRODUCTION DATA
| PWR_STAT 0x21 | ||||||||
|---|---|---|---|---|---|---|---|---|
| Bit7 | Bit6 | Bit5 | Bit4 | Bit3 | Bit2 | Bit1 | Bit0 | |
| Default after POR | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| Read | BUCK_FAIL | VREG_FAIL | OT_BUCK | OT_LDO | OT_BOOST | LDO_FAIL | BOOST_FAIL | HS_OL |
| Write | d.c. | d.c. | d.c. | d.c. | d.c. | d.c. | d.c. | d.c. |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| BUCK_FAIL | 7 | BUCK power fail flag | |
| 0: | |||
| 1: | Power stages shutdown detected caused by OC BUCK1, UV, OV, loss of GND (BOOST + all bucks) | ||
| BUCK_FAIL flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| VREG_FAIL | 6 | Internal voltage regulator too low | |
| 0: | |||
| 1: | VREG fail | ||
| VREG_FAIL flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| OT_BUCK | 5 | BUCK1-3 overtemperature flag | |
| 0: | |||
| 1: | IC power stages shutdown due to overtemperature | ||
| OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| OT_LDO | 4 | LDO overtemperature flag | |
| 0: | |||
| 1: | LDO shutdown due to overtemperature | ||
| OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| OT_BOOST | 3 | BOOST overtemperature flag | |
| 0: | |||
| 1: | BOOST shutdown due to overtemperature | ||
| OT flag is cleared in case the fail condition is not present anymore and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| LDO_FAIL | 2 | LDO under or overvoltage flag | |
| 0: | |||
| 1: | LDO out of regulation | ||
| LDO_FAIL flag is cleared if there is no undervoltage and no overvoltage and the flag is transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| BOOST_FAIL | 1 | Booster under or overvoltage flag or loss of GND | |
| 0: | |||
| 1: | Booster out of regulation | ||
| BOOST_FAIL flag is cleared if there is no undervoltage and no overvoltage and the flag was transmitted to the controller. | |||
| Bit Name | Bit No. | Description | |
|---|---|---|---|
| HS_OL | 0 | High-side switch open load condition | |
| 0: | |||
| 1: | Open load at high side | ||
| Bit indicates current OL condition of high side (no flag) | |||