ZHCSEW6G may 2013 – november 2020 DS90UB913A-Q1
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | NOM | MAX | UNIT | |
|---|---|---|---|---|---|---|
| RECOMMENDED INPUT TIMING REQUIREMENTS | ||||||
| fSCL | SCL Clock Frequency | Standard Mode | 100 | kHz | ||
| Fast Mode | 400 | kHz | ||||
| tLOW | SCL Low Period | Standard Mode | 4.7 | µs | ||
| Fast Mode | 1.3 | µs | ||||
| tHIGH | SCL High Period | Standard Mode | 4.0 | µs | ||
| Fast Mode | 0.6 | µs | ||||
| tHD:STA | Hold time for a start or a repeated start condition | Standard Mode | 4.0 | µs | ||
| Fast Mode | 0.6 | µs | ||||
| tSU:STA | Set Up time for a start or a repeated start condition | Standard Mode | 4.7 | µs | ||
| Fast Mode | 0.6 | µs | ||||
| tHD:DAT | Data Hold Time | Standard Mode | 0 | 3.45 | µs | |
| Fast Mode | 0 | 900 | ns | |||
| tSU:DAT | Data Set Up Time | Standard Mode | 250 | ns | ||
| Fast Mode | 100 | ns | ||||
| tSU:STO | Set Up Time for STOP Condition | Standard Mode | 4.0 | µs | ||
| Fast Mode | 0.6 | µs | ||||
| tBUF | Bus Free time between Stop and Start | Standard Mode | 4.7 | µs | ||
| Fast Mode | 1.3 | µs | ||||
| tr | SCL & SDA Rise Time | Standard Mode | 1000 | ns | ||
| Fast Mode | 300 | ns | ||||
| tf | SCL & SDA Fall Time | Standard Mode | 300 | ns | ||
| Fast Mode | 300 | ns | ||||