When a signal monitoring error occurs, the signal monitoring is disabled by clearing MUNIT_x_CTL.EN. In addition, further captures are disabled by clearing ECCTL1.CAPLDEN, but time stamp values in CAP1..4 are retained for debug purpose. To re-enable signal monitoring MUNIT_x_CTL.EN and ECCTL1.CAPLDEN need to be set again. CEVTx is generated even after an error is detected and further captures are disabled.