RSVD (Bits 23–16): Reserved. Do not use. |
|
TAPER (Bit 15): This is set when the Taper voltage condition is satisfied while charging. |
| 1 = | Taper voltage condition is satisfied during charge. |
| 0 = | Taper voltage condition is not satisfied during charge. |
|
RSVD (Bits 14–11): Reserved. Do not use. |
|
CCC (Bit 10): Charging Loss Compensation |
| 1 = | Active |
| 0 = | Inactive |
| | |
CVR (Bit 9): Charging Voltage Rate of Change |
| 1 = | Active |
| 0 = | Inactive |
| | |
CCR (Bit 8): Charging Current Rate of Change |
| 1 = | Active |
| 0 = | Inactive |
| | |
VCT (Bit 7): Charge Termination |
| 1 = | Active |
| 0 = | Inactive |
| | |
MCHG (Bit 6): Maintenance Charge |
| 1 = | Active |
| 0 = | Inactive |
| | |
SU (Bit 5): Charge Suspend |
| 1 = | Charge suspend active |
| 0 = | Charge suspend inactive |
| | |
IN (Bit 4): Charge Inhibit |
| 1 = | Active |
| 0 = | Inactive |
| | |
HV (Bit 3): High Voltage Region |
| 1 = | Active |
| 0 = | Inactive |
| | |
MV (Bit 2): Mid Voltage Region |
| 1 = | Active |
| 0 = | Inactive |
| | |
LV (Bit 1): Low Voltage Region |
| 1 = | Active |
| 0 = | Inactive |
| | |
PV (Bit 0): Precharge Voltage Region |
| 1 = | Active |
| 0 = | Inactive |