Sticky register used to indicate the source of an interrupt trigger
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| INT_WCHLT | INT_MCHLT | Reserved | Reserved | Reserved | |||
| R-0h | R-0h | R-0h | R-0h | R-0h | |||
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | INT_WCHLT | R | 0h | Sticky bit indicating that WCLK clock halt condition
0 = did not occurred since last read 1 = occurred since last read |
| 6 | INT_MCHLT | R | 0h | Sticky bit indicating that the modulator clock halt condition
0 = did not occurred since last read 1 = occurred since last read |
| 5-2 | Reserved | R | 0h | Reserved |
| 1 | Reserved | R | 0h | Reserved |
| 0 | Reserved | R | 0h | Reserved |