ZHCSQZ8A May   2022  – December 2022 ADS1285

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements: 1.65 V ≤ IOVDD ≤ 1.95 V and 2.7 V ≤ IOVDD ≤ 3.6 V
    7. 6.7 Switching Characteristics: 1.65V ≤ IOVDD ≤ 1.95V and 2.7 V ≤ IOVDD ≤ 3.6 V
    8. 6.8 Timing Diagrams
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Noise Performance
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Analog Input
      2. 8.3.2 PGA and Buffer
        1. 8.3.2.1 Programmable Gain Amplifier (PGA)
        2. 8.3.2.2 Buffer Operation (PGA Bypass)
      3. 8.3.3 Voltage Reference Input
      4. 8.3.4 IOVDD Power Supply
      5. 8.3.5 Modulator
        1. 8.3.5.1 Modulator Overdrive
      6. 8.3.6 Digital Filter
        1. 8.3.6.1 Sinc Filter Section
        2. 8.3.6.2 FIR Filter Section
        3. 8.3.6.3 Group Delay and Step Response
          1. 8.3.6.3.1 Linear Phase Response
          2. 8.3.6.3.2 Minimum Phase Response
        4. 8.3.6.4 HPF Stage
      7. 8.3.7 Clock Input
      8. 8.3.8 GPIO
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power Modes
      2. 8.4.2 Power-Down Mode
      3. 8.4.3 Reset
      4. 8.4.4 Synchronization
        1. 8.4.4.1 Pulse-Sync Mode
        2. 8.4.4.2 Continuous-Sync Mode
      5. 8.4.5 Sample Rate Converter
      6. 8.4.6 Offset and Gain Calibration
        1. 8.4.6.1 OFFSET Register
        2. 8.4.6.2 GAIN Register
        3. 8.4.6.3 Calibration Procedure
    5. 8.5 Programming
      1. 8.5.1 Serial Interface
        1. 8.5.1.1 Chip Select (CS)
        2. 8.5.1.2 Serial Clock (SCLK)
        3. 8.5.1.3 Data Input (DIN)
        4. 8.5.1.4 Data Output (DOUT)
        5. 8.5.1.5 Data Ready (DRDY)
      2. 8.5.2 Conversion Data Format
      3. 8.5.3 Commands
        1. 8.5.3.1  Single Byte Command
        2. 8.5.3.2  WAKEUP: Wake Command
        3. 8.5.3.3  STANDBY: Software Power-Down Command
        4. 8.5.3.4  SYNC: Synchronize Command
        5. 8.5.3.5  RESET: Reset Command
        6. 8.5.3.6  Read Data Direct
        7. 8.5.3.7  RDATA: Read Conversion Data Command
        8. 8.5.3.8  RREG: Read Register Command
        9. 8.5.3.9  WREG: Write Register Command
        10. 8.5.3.10 OFSCAL: Offset Calibration Command
        11. 8.5.3.11 GANCAL: Gain Calibration Command
    6. 8.6 Register Map
      1. 8.6.1 Register Descriptions
        1. 8.6.1.1 ID/SYNC: Device ID, SYNC Register (Address = 00h) [Reset = xxxx0000b]
        2. 8.6.1.2 CONFIG0: Configuration Register 0 (Address = 01h) [Reset = 12h]
        3. 8.6.1.3 CONFIG1: Configuration Register 1 (Address = 02h) [Reset = 00h]
        4. 8.6.1.4 HPF0, HPF1: High-Pass Filter Registers (Address = 03h, 04h) [Reset = 32h, 03h]
        5. 8.6.1.5 OFFSET0, OFFSET1, OFFSET2: Offset Calibration Registers (Address = 05h, 06h, 07h) [Reset = 00h, 00h, 00h]
        6. 8.6.1.6 GAIN0, GAIN1, GAIN2: Gain Calibration Registers (Address = 08h, 09h, 0Ah) [Reset = 00h, 00h, 40h]
        7. 8.6.1.7 GPIO: Digital Input/Output Register (Address = 0Bh) [Reset = 000xx000b]
        8. 8.6.1.8 SRC0, SRC1: Sample Rate Converter Registers (Address = 0Ch, 0Dh) [Reset = 00h, 80h]
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
      1. 9.3.1 Analog Power Supplies
      2. 9.3.2 Digital Power Supply
      3. 9.3.3 Grounds
      4. 9.3.4 Thermal Pad
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  10. 10Device and Documentation Support
    1. 10.1 接收文档更新通知
    2. 10.2 支持资源
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • RHB|32
散热焊盘机械数据 (封装 | 引脚)
订购信息

Commands

Table 8-11 lists the commands for the ADC. Most commands are one byte in length. However, the number of bytes for the register read and write commands depend on the amount of register data specified in the command.

Table 8-11 Command Descriptions
MNEMONIC TYPE DESCRIPTION BYTE 1(1) BYTE 2
WAKEUP Control Wake from standby mode or NOP 0000 000x (00h or 01h)
STANDBY Control Enter standby (software power-down mode) 0000 001x (02h or 03h)
SYNC Control Synchronize 0000 010x (04h or 5h)
RESET Control Reset 0000 011x (06h or 07h)
RDATA Data Read conversion data 0001 0010 (12h)
RREG Register Read nnnn registers beginning at address rrrr 0010 rrrr (20h + rrrr)(2) 0000 nnnn (00h + nnnn)(3)
WREG Register Write nnnn registers beginning at address rrrr 0100 rrrr (40h + rrrr)(2) 0000 nnnn (00h + nnnn)(3)
OFSCAL Calibration Offset calibration 0110 0000 (60h)
GANCAL Calibration Gain calibration 0110 0001 (61h)
x = Don't care.
rrrr = Starting address for register read and write commands.
nnnn = Number of registers to be read or written – 1. For example, to read or write three registers, nnnn = 2.