ZHCSJM7 April 2019 BQ79606A-Q1
PRODUCTION DATA.
| SYS_FLT3_RST Register Address: 0x13D | |||||||
| B7 | B6 | B5 | B4 | B3 | B2 | B1 | B0 |
| RSVD | AUX_FILT_RST | LP_FILT_RST | VIOUV_RST | CB_VDONE_RST | LFO_RST | SEC_DET_RST | DED_DET_RST |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| R | rw | rw | RW | RW | rw | RW | RW |
| RSVD | Reserved | ||||||
| AUX_FILT_RST | Resets SYS_FAULT3[AUX_FILT] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| LP_FILT_RST | Resets SYS_FAULT3[LP_FILT] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| VIOUV_RST | Resets SYS_FAULT3[VIOUV_RST] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| CB_VDONE_RST | Resets SYS_FAULT3[CB_VDONE] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| LFO_RST | Resets SYS_FAULT3[LFO] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| SEC_DET_RST | Resets SYS_FAULT3[SEC_DETECT] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
| DED_DET_RST | Resets SYS_FAULT3[DED_DETECT] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||