ZHCSJM7 April 2019 BQ79606A-Q1
PRODUCTION DATA.
UV_FLT_RST Register Address: 0x128 | |||||||
B7 | B6 | B5 | B4 | B3 | B2 | B1 | B0 |
RSVD[1] | RSVD[0] | CELL6_RST | CELL5_RST | CELL4_RST | CELL3_RST | CELL2_RST | CELL1_RST |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
R | R | RW | RW | RW | RW | RW | RW |
RSVD[1:0] | Reserved | ||||||
CELL6_RST | Resets UV_FAULT[CELL6] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
CELL5_RST | Resets UV_FAULT[CELL5] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
CELL4_RST | Resets UV_FAULT[CELL4] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
CELL3_RST | Resets UV_FAULT[CELL3] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
CELL2_RST | Resets UV_FAULT[CELL2] to '0'
0: Do not reset 1: Reset Always reads '0' |
||||||
CELL1_RST | Resets UV_FAULT[CELL1] to '0'
0: Do not reset 1: Reset Always reads '0' |