ZHCSJM7 April 2019 BQ79606A-Q1
PRODUCTION DATA.
| GPIO_ADC_CONF Register Address: 0x28 | |||||||
| B7 | B6 | B5 | B4 | B3 | B2 | B1 | B0 |
| SPARE[1] | SPARE[0] | GPIOCONF6 | GPIOCONF5 | GPIOCONF4 | GPIOCONF3 | GPIOCONF2 | GPIOCONF1 |
| 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| RW | RW | RW | RW | RW | RW | RW | RW |
| SPARE[1:0] | Spare | ||||||
| GPIOCONF6 | Configures ADC result for GPIO6 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||
| GPIOCONF5 | Configures ADC result for GPIO5 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||
| GPIOCONF4 | Configures ADC result for GPIO4 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||
| GPIOCONF3 | Configures ADC result for GPIO3 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||
| GPIOCONF2 | Configures ADC result for GPIO2 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||
| GPIOCONF1 | Configures ADC result for GPIO1 as ratiometric or an absolute measurement
0: Temperature sensor monitor (ratiometric result) 1: AUX voltage measurement (absolute voltage result) |
||||||