ZHCSUF1B January 2024 – June 2024 TPS7H3014-SP
PRODUCTION DATA
If active, the REG_TMR will monitor the time a VOUTx takes to cross the VONx voltage once the ENx signal is forced high. In the case the REG_TMR is expired and VOUTx has not crossed the VONx voltage, a reverse sequence down from the previously sequenced rail will be started as described in the State Machine section. Figure 8-8 shows the REG_TMR active during sequence up, from the time ENx is forced high (VOUTx starts rising). In this case, VOUTx always crosses VON before the timer is expired. The REG_TMR resistor can be selected using Equation 17 and Equation 18. Figure 8-11 or Figure 8-12 shows the linear trend between the REG_TMR resistor and the regulation time allowed for the rail to be in regulation (VOUTx > VONx).
For tDLY_TMR between 0.264ms and 12.4ms use:
For tDLY_TMR greater than 12.4ms use:
Table 8-2 shows typical resistor values for different allowed regulation times.
tREG_TMR (ms) | RREG_TMR (kΩ) |
---|---|
0.264 | 10.5 |
12.4 | 619 |
23.63 | 1180 |