ZHCSE74C September 2015 – May 2025 LMK61E2
PRODUCTION DATA
The PLL has charge pump slices of 1.6mA, to be used when PLL is set to fractional mode, or 6.4mA, to be used when PLL is set to integer mode. These slices can be selected by programming R34[3-0]. When PLL is set to fractional mode, a phase shift needs to be introduced to maintain a linear response and verify consistent performance across operating conditions and a value of 0x2 must be programmed in R35[6-4]. When PLL is set to integer mode, a value of 0x0 must be programmed in R35[6-4].