ZHCSGZ6A October 2017 – February 2025 TPS6508700
PRODUCTION DATA
TEMPHOT is shown in Figure 6-65 and described in Table 6-59.
Return to Summary Table.
Asserted when an internal temperature sensor detects rise of die temperature above the HOT temperature threshold (THOT). There are 5 temperature sensors across the die.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | DIE_HOT | VTT_HOT | TOP-RIGHT_HOT | TOP-LEFT_HOT | BOTTOM-RIGHT_HOT | ||
| R-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | ||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-5 | RESERVED | R | 0h | |
| 4 | DIE_HOT | R/W | 0h | Temperature of rest of die has exceeded THOT. 0h = Not asserted. 1h = Asserted. The host to write 1 to clear. |
| 3 | VTT_HOT | R/W | 0h | Temperature of VTT LDO has exceeded THOT. 0h = Not asserted. 1h = Asserted. The host to write 1 to clear. |
| 2 | TOP-RIGHT_HOT | R/W | 0h | Temperature of Top-Right has exceeded THOT. Top-Right corner of die from top view given pin1 is in Top-Left corner. 0h = Not asserted. 1h = Asserted. The host to write 1 to clear. |
| 1 | TOP-LEFT_HOT | R/W | 0h | Temperature of Top-Left has exceeded THOT. Top-Left corner of die from top view given pin1 is in Top-Left corner. 0h = Not asserted. 1h = Asserted. The host to write 1 to clear. |
| 0 | BOTTOM-RIGHT_HOT | R/W | 0h | Temperature of Bottom-Right has exceeded THOT. Bottom-Right corner of die from top view given pin1 is in Top-Left corner. 0h = Not asserted. 1h = Asserted. The host to write 1 to clear. |