ZHCSG76A April 2017 – March 2025 INA233
PRODUCTION DATA
READ_VIN is a standard PMBus command that returns the 16-bit measured value of the input voltage as read from the VBUS pin. Use the coefficients listed in Table 6-1 to read this register. Use the PMBus read word protocol to access this command. This value is also used internally for the VIN_OV_WARN and VIN_UV_WARN detection.
| VALUE | MEANING | DEFAULT |
|---|---|---|
| 0h–7FFFh | Measured value for VBUS | 0000h |
Full-scale range = 40.96V (7FFFh) and LSB = 1.25mV.