SLUUCG7 April 2024 BQ76922
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CUDEP | SOTF | RSVD_0 | SOT | SOCD | SOCC | SOV | SUV |
Description: Saved Permanent Failure Status A
| Bit | Field | Description |
|---|---|---|
| 7 | CUDEP | 0 = Copper Deposition Permanent Fail did not occur 1 = Copper Deposition Permanent Fail occurred |
| 6 | SOTF | 0 = Safety FET Overtemperature Permanent Fail did not occur 1 = Safety FET Overtemperature Permanent Fail occurred |
| 4 | SOT | 0 = Safety Cell Overtemperature Permanent Fail did not occur 1 = Safety Cell Overtemperature Permanent Fail occurred |
| 3 | SOCD | 0 = Safety Overcurrent in Discharge Permanent Fail did not occur 1 = Safety Overcurrent in Discharge Permanent Fail occurred |
| 2 | SOCC | 0 = Safety Overcurrent in Charge Permanent Fail did not occur 1 = Safety Overcurrent in Charge Permanent Fail occurred |
| 1 | SOV | 0 = Safety Cell Overvoltage Permanent Fail did not occur 1 = Safety Cell Overvoltage Permanent Fail occurred |
| 0 | SUV | 0 = Safety Cell Undervoltage Permanent Fail did not occur 1 = Safety Cell Undervoltage Permanent Fail occurred |