ZHCS089G February 2011 – September 2017 TPS65185
PRODUCTION DATA.
NOTE: PG pin is pulled hi (HiZ state) when VDDH_PG = VPOS_PG = VEE_PG = VNEG_PG = 1
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| VB_PG | VDDH_PG | VN_PG | VPOS_PG | VEE_PG | Not used | VNEG_PG | Not used |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | VB_PG | R | 0h | Positive boost converter power good
0h = DCDC1 is not in regulation or turned off 1h = DCDC1 is in regulation |
| 6 | VDDH_PG | R | 0h | VDDH power good
0h = VDDH charge pump is not in regulation or turned off 1h = VDDH charge pump is in regulation |
| 5 | VN_PG | R | 0h | Inverting buck-boost power good
0h = DCDC2 is not in regulation or turned off 1h = DCDC2 is in regulation |
| 4 | VPOS_PG | R | 0h | VPOS power good
0h = LDO1(VPOS) is not in regulation or turned off 1h = LDO1(VPOS) is in regulation |
| 3 | VEE_PG | R | 0h | VEE power good
0h = VEE charge pump is not in regulation or turned off 1h = VEE charge pump is in regulation |
| 2 | Not used | R | 0h | Not used |
| 1 | VNEG_PG | R | 0h | VNEG power good
0h = LDO2(VNEG) is not in regulation or turned off 1h = LDO2(VNEG) is in regulation |
| 0 | Not used | R | 0h | Not used |