ZHCS089G February 2011 – September 2017 TPS65185
PRODUCTION DATA.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| READ_THERM | Not used | CONV_END | Not used | Not used | Not used | DT[1:0] | |
| R/W-0h | R/W-0h | R-1h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | READ_THERM | R/W | 0h | Read thermistor value
0h = No effect 1h = Initiates temperature acquisition NOTE: Bit is self-cleared after acquisition is completed |
| 6 | Not used | R/W | 0h | Not used |
| 5 | CONV_END | R | 1h | ADC conversion done flag
0h = Conversion is not finished 1h = Conversion is finished |
| 4 | Not used | R/W | 0h | Not used |
| 3 | Not used | R/W | 0h | Not used |
| 2 | Not used | R/W | 0h | Not used |
| 1-0 | DT | R/W | 0h | Panel temperature-change interrupt threshold
0h = 2°C 1h = 3°C 2h = 4°C 3h = 5°C DTX interrupt is issued when difference between most recent temperature reading and baseline temperature is equal to or greater than threshold value. See Hot, Cold, and Temperature-Change Interrupts for details. |