ZHCS089G February 2011 – September 2017 TPS65185
PRODUCTION DATA.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| VB_UV | VDDH_UV | VN_UV | VPOS_UV | VEE_UV | VCOMF | VNEG_UV | EOC |
| R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | VB_UV | R | N/A | Positive boost converter undervoltage detect interrupt
0h = No fault 1h = Under-voltage on DCDC1 detected |
| 6 | VDDH_UV | R | N/A | VDDH under voltage detect interrupt
0h = No fault 1h = Undervoltage on VDDH charge pump detected |
| 5 | VN_UV | R | N/A | Inverting buck-boost converter under voltage detect interrupt
0h = No fault 1h = Undervoltage on DCDC2 detected |
| 4 | VPOS_UV | R | N/A | VPOS undervoltage detect interrupt
0h = No fault 1h = Undervoltage on LDO1(VPOS) detected |
| 3 | VEE_UV | R | N/A | VEE undervoltage detect interrupt
0h = No fault 1h = Undervoltage on VEE charge pump detected |
| 2 | VCOMF | R | N/A | VCOM fault detection
0h = No fault 1h = Fault on VCOM detected (VCOM is outside normal operating range) |
| 1 | VNEG_UV | R | N/A | VNEG undervoltage detect interrupt
0h = No fault 1h = Undervoltage on LDO2(VNEG) detected |
| 0 | EOC | R | N/A | ADC end of conversion interrupt
0h = No significance 1h = ADC conversion is complete (temperature acquisition is complete) |