SLVSHZ5 November 2026 TPS544628
ADVANCE INFORMATION
VOUT_OV_FAULT_RESPONSE is shown in Figure 7-15 and described in Table 7-21.
Return to the Summary Table.
Write Transaction: Write Byte
Read Transaction: Read Byte
Data Format: Unsigned Binary (1 byte)
NVM Back-up: EEPROM
Updates: On-the-fly The VOUT_OV_FAULT_RESPONSE command instructs the device on what action to take in response to an output over-voltage fault.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | RS_OV | TD_OV | |||||
| R-0h | R/W-Xh | R-0h | |||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-6 | RESERVED | R | 0h | Reserved |
| 5-3 | RS_OV | R/W | X | Output voltage over voltage retry setting. On reset the value will be determined by NVM.
|
| 2-0 | TD_OV | R | 0h | These set the delay from the detection of the fault condition signal to the rail shutting down.
|