ZHCSKO3B January 2020 – September 2020 BQ25611D
PRODUCTION DATA
When battery is discharged below VBAT_DPL_FALL, the BATFET will latch off to protect battery from over discharge. To recover from over-discharge latch-off, an input source plug-in is required at VAC/VBUS.