ZHCSUI2E May 2006 – January 2024 TPS28225
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| SWITCHING TIME | ||||||
| tDLU | UGATE turn-off propagation Delay | CL = 3 nF | 14 | ns | ||
| tDLL | LGATE turn-off propagation Delay | CL = 3 nF | 14 | ns | ||
| tDTU | Dead time LGATE turn off to UGATE turn on | CL = 3 nF | 14 | ns | ||
| tDTL | Dead time UGATE turn off to LGATE turn on | CL = 3 nF | 14 | ns | ||
Figure 5-1 TPS28225 Timing Diagram