9 Revision History
Changes from Revision C (November 2014) to Revision D (February 2024)
- 在整个数据表中添加了包容性术语Go
- Changed pin 22 from: TVC + to: TXC+
Go
- Updated MSEN pin description from: when I2C is
disabled (ISEL = low), a low level indicates a powered on receiver is
detected at the differential outputs. A high level indicates a powered on
receiver is not detected to: when I2C is disabled (ISEL =
low), a high level indicates a powered on receiver is detected at the
differential outputs. A low level indicates a powered on receiver is not
detected.
Go
- Changed pin 6 name from CTL3/A3/DK3 to A3/DK3.Go
- Changed from: When the I2C bus is disabled (ISEL = low) and the
de-skew mode is disabled (DKEN = low), these three inputs become the control
inputs, CTL[3:1], which can be used to send additional information across
the DVI link during the blanking interval (DE = low). The CTL3 input is
reserved for HDCP compliant DVI TXs (TFP510) and the CTL[2:1] inputs are
reserved for future use. to: When the I2C bus is disabled
(ISEL = low) and the de-skew mode is disabled (DKEN = low), pins 7 and 8
become the control inputs, CTL[2:1], which can be used to send additional
information across the DVI link during the blanking interval (DE = low). Pin
6 is not used.
Go
- Updated
VIH and VIL for Data, DE, VSYNC, HSYNC, and IDCK+/-
CMOS inputs and the remaining CMOS inputsGo
- Changed
three
user definable control signals, CTL[3:1], during the inactive display or
blanking interval
to:
three
control signals, CTL[3:1], during the inactive display or blanking
interval
Go
- Changed
the
TFP410 encodes and transfers the CTL[3:1] inputs
during the vertical blanking interval
to:
the
TFP410 encodes and transfers the CTL[2:1] inputs
during the vertical blanking
interval
Go
- Changed
the
CTL3 input is reserved for HDCP compliant DVI TXs and the CTL[2:1] inputs
are reserved for future use
to:
CTL3
is reserved for HDCP and is always encoded as 0. The CTL[2:1] inputs are
reserved for future
use
Go
- Changed RW field for sub-address 0B from RW to R. Go
- Changed CTL_1_MODE register reset value from: 0xFE to:
0xBE
Go
- Changed in the CTL_3_MODE register, bit 3 from CTL3 to
RSVD
Go
- Added in DE_DLY register the value must be less than or equal to
(2047 - DE_CNT)
Go
- Added in the DE_CNT register the value must be less than or equal
to (2047 - DE_DLY)
Go
- Changed Application Information summary to be focused on TFP410 instead of the TDP401.Go
Changes from Revision B (May 2011) to Revision C (November 2014)
- 添加了 ESD 等级 表、热性能信息 表、典型特性 部分、特性说明 部分、器件功能模式、应用和实施 部分、电源相关建议 部分、布局 部分、器件和文档支持 部分以及机械、封装和可订购信息 部分。Go