ZHCSSI3 February 2024 ADS1288
PRODUCTION DATA
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED | DR[2:0] | PHASE | FILTR[1:0] | ||||
R-10b | R/W-010b | R/W-0b | R/W-10b |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7:6 | RESERVED | R | 10b | Reserved bits |
5:3 | DR[2:0] | R/W | 010b | Data rate selection. See the Digital Filter section for details. 000b = 125SPS 001b = 250SPS 010b = 500SPS 011b = 1000SPS 100b = 2000SPS 101b –111b = Reserved |
2 | PHASE | R/W | 0b | FIR
filter phase selection. See the Digital Filter section for details. 0b = Linear phase 1b = Minimum phase |
1:0 | FILTR[1:0] | R/W | 10b | Digital
filter configuration. See the Digital Filter section for details. 00b = Reserved 01b = Sinc filter output 10b = FIR filter output 11b = FIR + IIR filter output |